Photon Design logoPhoton Design
LinkedIn Contact
Website News Thumbnails 3
7 Oct 2026

FIMMWAVE 8.2 - Brand new applications for eigenmode expansion including advanced TFLN support.

TFLN for high speed data transmission, enabling precision for quantum application, and new large scale PIC components.

Further pioneering Photon Design’s leading EME simulation tools, FIMMWAVE’s 8.2 update provides ground breaking achievements for the EME method as a whole and greatly improves usability to achieve  accurate simulations:

 

Advanced TFLN simulations - taking simulations from hours to seconds.

FIMMPROP can now natively simulate propagation through birefringent materials unlike any other EME solver on the market. The most commonly known of these, thin film lithium niobate TFLN, is an essential for high speed signal transmission. Until now, capturing the birefringence of TFLN bends has required lengthy FDTD simulations which scale with the large bounding volume of the bend. Now, FIMMPROP EME simulates TFLN bends in a matter of seconds regardless of their footprint on the PIC.

 

Photon Design completes TFLN waveguide ‘S’ bend simulations natively, in just 10 seconds.

Advancements in Photon Design’s EME allow new applications for birefringent materials like TFLN

In the past, MT-FIMMPROP has allowed TFLN designers to simulate an entire modulator including the effects of an applied voltage or thermal source.

Full 3D Mach Zehnder Modulator (TFLN)

Unique - MT-FIMMPROP simulates full modulator rigorously in layout environment

Large scale component simulations

The unique EME application MT-FIMMPROP that simulates larger scale PIC components receives further options to define waveguide geometry. With improved flexibility is shown with a new example showing 3D rigorous simulations of a curved directional coupler - giving a broadband response over their linear counterpart.

This release also makes many new MT-FIMMPROP examples available to users:

Pulley Coupler

Use MT-FIMMPROP to simulate the fabrication error tolerant pulley coupler in seconds

Cascaded MMIs

Connect multiple MMIs together nativly in a layout environment

Curved Directional Coupler

The standard straight directional coupler exhibits a large wavelength dependence that can be undesirable. A more broadband curved directional coupler simulated in 3D with MT-FIMMPROP.

Vernier Mirror with Ring Resonators

100 um rings simulated in 3D in a single simulation environment.

Making accurate simulations more simple to reach

With all solver parameters now available to control by the in-software variables list, engineers can now much more easily test the convergence of their simulations using variable scans.

Engineers at Photon Design have recently demonstrated with a waveguide taper a convergence to the micro dB level desired for the precise demands of quantum applications.

Micro dB Convergence for Quantum Device Applications

Simulation accuracy and precision are paramount for engineers on the cutting edge of quantum applications where losses are unacceptable. FIMMPROP convergences on results shown of order 10⁻⁶ dB.

Full Release Notes

 

New for FIMMWAVE Version 8.2:

• All solver parameters can now be set to expressions involving variables. This makes it much easier to perform convergence tests with respect to solver parameters. 

• All solver parameters can now be accessed and edited individually via the command-line. Previously, modifying a single solver parameter required the whole solver parameter buff string to be specified. 

• It is now possible to specify the orientation of a waveguide relative to the coordinate system of the material database, which is relevant if the waveguide references any anisotropic materials. 

• The RIX profile of an MWG shape now supports full non-diagonal permittivity and permeability tensors. 

• Introduction of the application option startupPort, which allows users to specify a TCPIP port that the application will automatically connect to on startup. 

• Introduction of the application option Imaginary eval type, which allows users to display the imaginary part of mode eigenvalues as either the imaginary part of an effective index (Im(neff)) or as mode loss (alpha). 

• The WG Scanner now gives users the option to continue when a step has failed. 

• The addition of mode width to the list of mode properties that can be tracked and plotted using a WG Scanner. 

• Introduction of the bspline mathematical function for use in expressions. 

• Introduction of the polar mathematical function for use in expressions, which allows users to specify a complex number in terms of its amplitude and phase. 

• It is now possible to set the heatsink to the top of the simulation window in the Thermal Profiler. 

• The command-line functions app.wgoverlap and app.modefileoverlap now work with command-line global objects and references that are waveguides. 

• The bounding rect of an MWG polygon no longer includes the origin of the polygon's coordinates. This may affect the alignment of some users’ polygons. 

• Improved handling of invalid expressions.

 

New for FIMMPROP v8.2:

• Introduced a new mode of operation for Planar Sections whereby a fab model is referenced and the Paths of the Planar Section are associated with process mask layers in the fab model. 

• In the original mode of operation for Planar Sections, where an SWG is referenced and Planar Section Paths have etch/grow parameters, the parameter profileType has been introduced. This allows users to specify a Tapered or Vertical profile for the sidewalls of the etch/grow process associated with the Path. 

• It is now possible to specify the orientation of a FIMMPROP device relative to the coordinate system of the material database, which is relevant if any of its sections reference anisotropic materials. 

• For FIMMPROP device input type mode index, the mode index can now be specified using an expression involving variables. Similarly, for the vector input type the mode amplitudes can be specified in terms of expressions involving variables. 

• The generation of XZ/YZ field profiles for a FIMMPROP device has been sped up. 

• Calculation Diagnostics tools have been sped up. 

• Calculation Diagnostics tools are now accessible via the command-line. 

• When using the Calculation Diagnostics tools, it is now possible to override the default behaviour whereby modes are assumed not to be power orthogonal if a complex solver is being used. This can help to speed up calculations in cases where it is known that modes are power orthogonal despite the fact that a complex solver is being used. 

• Mode width can now be plotted when inspecting Mode Data vs Z for a FIMMPROP device. 

• Mode Data Z-profiles for a FIMMPROP device are now accessible via the command-line. 

• The Taper Algorithm can now handle the case where fewer than maxNmodes are found at some positions along a taper. This may happen if MOLAB Filters are being used and there are fewer than maxNmodes modes that satisfy the filters at some position along the taper. 

• The temperature used by WG Sections and Constant Bend Sections is now that of the parent device rather than that of the referenced Waveguide Node. This may affect some users’ simulations. 

• The waveguide generated by a Planar Section to represent its cross-section at a given Z-positon is now an MWG rather than an RWG. This is to accommodate the larger range of cross-section shapes that it is now possible to achieve. This may affect users’ scripts if they use the getwg command-line function and assume that the returned waveguide is an RWG. 

• In the original mode of operation of a Planar Section, where an SWG is referenced and Planar Section Paths have etch/grow parameters, the behaviour of etch Paths has been modified. When etch Paths overlap, the resulting etch depth will now be the largest etch depth of the overlapping Paths. Previously the etch depth was determined by that of Path highest in the list of Paths.

 

New for MT-FIMMPROP v1.2 (for FIMMWAVE v8.2):

• Introduced curvature paths, which allow you to specify a path in terms of the curvature along its length. See §3.3.6. 

• Introduced fab models, which allow you to share physical layers and process mask layers between multiple MT devices. See §3.2. • The generation of plan-view field profiles for MT devices has been sped up. 

• When specifying the input of an MT device, for input type Single Mode the mode index can now be specified in terms of an expression involving variables. Similarly, for input type Vector the mode amplitudes can be specified in terms of expressions involving variables.

Latest from Photon Design

Latest news and exhibitions Visit the Newsroom for more.